Filling In the Sigmafine Balance Quantity Output Tab

The Quantity Output tab contains the selection of output Attributes for the elements in the model. These Attributes hold the values for the reconciled measurement and tolerance, as well as statistical results, such as Solvability and Imbalance. The selected values and tolerances are the outputs from the Sigmafine Reconciliation engine.Figure 236: Sigmafine Balance Configuration - Quantity Output tab

The following tables define the parameters configured on the Quantity Output tab.

Quantity Output Tab – Measurements and Flows

ElementParameterDescriptionDefault Attribute Name
MetersInventoriesTransfersStreamsReconciled StatusReconcile inferred operation status after the analysis is performed.InferredStatus
MetersInventoriesTransfersStreamsReconciled MeasurementReconcile value that Sigmafine calculates for a measurement when analysis is run.ReconciledMass
MetersInventoriesTransfersStreamsReconciled ToleranceReconcile tolerance Sigmafine calculates for a tolerance when an analysis is run.ReconciledMassTolerance
MetersInventoriesTransfersStreamsSolvabilityReconcile solvability status from the solvability analysis. Values are:R – RedundantS – SolvableNS – Not solvableNR – Not RedundantUS – Unknown SolvabilityReconciledMassSolvability
MetersInventoriesTransfersStreamsInfluenceReconcile influence value that indicates a measurement’s effect on the balance result set if the measurement is changed or removed completely from the balance. Values between -1 and 1.ReconciledInfluence
MetersInventoriesTransfersStreamsReconciled AdjustmentReconcile adjustment value that is the difference between the reconciled value and the measured value.ReconciledMassCorrection
MetersInventoriesTransfersStreamsTest 1Statistical test value Sigmafine calculates when an analysis is run. The value represents the measurement correction ratio to its tolerance.ReconciledMassTest1
MetersInventoriesTransfersStreamsTest 2Statistical test value Sigmafine calculates when an analysis is run. The value represents the measurement correction ratio to its reconciled toleranceReconciledMassTest2

Quantity Output Tab – Balances

ElementParameterDescriptionDefault Attribute Name
NodesInventoriesProcessesInitial ImbalanceReconcile initial imbalance value that represents the quantity difference between the sum of measured flows into a balance Element and the sum of measured flows out.ReconciledMassImbalance
NodesInventoriesProcessesVarianceReconcile variance value calculated from the uncertainties of input and output flows of the balance point.ReconciledMassVariance
NodesInventoriesProcessesTest 3Statistical test value Sigmafine calculates when an analysis is run. Referred to as the Imbalance Ratio, it represents the division of the balance error by the balance variance and is a measure of the magnitude of the imbalance.ReconciledMassTest3
NodesInventoriesProcessesTest 4Test 4, based on Test3, except normalized by the Balance Test Critical Value.ReconciledMassTest4
NodesInventoriesProcessesReconciled ResidualThe Reconciled Residual is the difference between the sum of the reconciled of all inputs and the sum of the reconciled of all outputs for balance elements.ReconciledResidual